multi EA 4000 Series The Workhorse for Your Solids Analysis
- Unique application diversity (TS, TC, TX, TOC, TIC, EC, AOC)
- Low maintenance and low operating costs
- Fully automated solids sampler for high sample throughput
- Durable design and long-living hardware components
The multi EA 4000 is the ideal partner for your solids analysis, offering safe automation, enhanced analysis precision and reliability thanks to patented innovative solutions. The system has been created to cope with the most diverse sample matrices, while keeping operating costs and maintenance low.
The All-Rounder in Solids Analysis
The multi EA 4000 guarantees the fully automated determination of TS, TC, TX contents and the environmentally relevant parameters TOC, TIC, EC, and BOC in soil, sediments, waste, minerals, and other organic and inorganic solids. Its modular design concept allows to expand the application range from an one element analyzer to a fully automated multi-element analysis system at any time. Convenient, flexible, and customized to meet your needs
- Wide-range NDIR detector for carbon and sulfur with a dynamic measuring range from ppm to weight percent
- HTC technology for catalyst-free high-temperature decomposition of even the most difficult matrices
- Robust, highly resistant ceramic combustion tubes – especially well-suited to analyze aggressive samples with less wear and low operating costs
- Durable heating elements ensure maximum operating time
- Simultaneous carbon and sulfur analysis, independent of the element contents
- Fully automated determination of TOC and TIC from a single sample in only one analysis step
- Easy chlorine determination up to the weight percent range
- Unique combination of elements: carbon, sulfur, and chlorine – especially interesting for waste analyses
- Flame sensor technology for matrix-optimized sample decomposition in chlorine analysis
- Self Check System for optimal operating safety
- Intuitive software navigation for easy operation and perfect measurement results
- Easy to use – preset methods for various applications greatly simplify work and save valuable measuring time
Brochures
Title | Language | Info |
---|---|---|
Broschüre multi EA 4000 (DE) | de | PDF, 407 KB |
Brochure multi EA 4000 (EN) | en | PDF, 408 KB |
Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
High Performance with Low Maintenance
The multi EA 4000 convinces with its durable design. The selected resistant materials are an advantage when analyzing aggressive and saline samples that cause a high degree of wear with traditional systems. A special optics arrangement and effective gas purification provide a resilient C/S detector that guarantees for extremely low maintenance and excellent long-term stability. Maintenance effort is reduced to a minimum while the operating time of the system is at maximum. Low operating costs and an absolutely reliable analyzing and measuring technique ensure each process step is as effective and efficient as possible.
- Use of robust and virtually wear-free ceramic combustion tubes instead of cost-intensive and quickly worn-out quartz combustion tubes
- Minimal chemical consumption thanks to high-temperature ceramic technology (HTC) – no catalysts needed
- No complex reduction and separation of the oxidation products (chromatographic via adsorption columns) required – due to the use of selective detectors for CO2, SO2 and HCl
- No auxiliary gas required for carbon and sulfur analysis
- High sample weights up to 3 g, no laborious sample homogenization required
Thanks to the variable gas flow management and the optimized wide range coulometer, chlorine analyses are possible from the low ppm up to the weight percent range. The coulometric detection system utilizes a unique patented combination electrode. The electrode is based on the latest ceramic technology and does not use internal electrolytes, membranes, or diaphragms. It is immediately ready for use and very low maintenance. The measuring cell is equipped with an automatic stirring function and a self-cleaning silver generator electrode. The integrated cooling of the coulometer cell minimizes electrolyte evaporation while in continuous operation and guarantees stable results. Compared with traditional electrolytes, the special electrolyte used has a significantly increased chloride absorption capacity. This results in long-term stability, which allows for uninterrupted routine analyses even with extremely high chloride loads and without bothersome electrolyte changes.
The challenge modern analytical systems for marco-elemental analysis face lies in reliable automation for an extensive range of samples. The multi EA 4000 offers the fully automatic determination of TOC based on the differential method. The FPG 48 solids sampler offers an enormous capacity for up to 48 sample boats to be transferred into the combustion furnace. Other accessories include modules for direct and automated determination of TIC and TOC. The multi EA 4000 with its high sample throughput is ideal for the automated analysis of carbon, sulfur, and chlorine, as well as the automated determination of total organic and inorganic carbon. By setting different waiting positions and feed speeds, samples of one and the same run each of them can be analyzed under optimal conditions. This means matrices requiring a special temperature program or gradient are processed easily and automatically together with others. An open gas lock replaces problematic sample ports that require opening and closing for sample introduction. It is completely maintenance-free, which avoids contamination and wear. A method library is included to ensure that the analysis of your sample is carried out optimally and reliably. The multi EA 4000 comes equipped with a Self Check System (SCS). The system automatically checks all relevant parameters such as flows and temperatures and guarantees trouble-free, fully automated operation with functions such as the automated gas shut-off and a low standby temperature at the end of an analysis sequence.
Products
multi EA 4000 C with pyrolysis option
Elemental analyzer for the determination of versatile carbon parameters (e.g., TC, RC, AOC), suited for organic and inorganic solids
Order number: 450-126.568
multi EA 4000 C
Elemental analyzer for the determination of carbon contents in organic and inorganic solids
Order number: 450-126.564
multi EA 4000 Cl
Elemental analyzer for the determination of total chlorine in organic solids, waste, and derived fuels
Order number: 450-126.566
multi EA 4000 CS
Elemental analyzer for the simultaneous determination of total carbon and total sulfur contents in organic and inorganic solids
Order number: 450-126.440
multi EA 4000 CS with pyrolysis option
Elemental analyzer for the determination of total sulfur and versatile carbon parameters (e.g. TC, RC, AOC), suited for organic and inorganic solids
Order number: 450-126.569
multi EA 4000 S
Elemental analyzer for the determination of total sulfur contents in organic and inorganic solids
Order number: 450-126.565
Applications
Applications
-
Determination of Total Chlorine in Derived or Secondary Fuels Using High-Temperature (EN)
Applications
-
Determination of Total Chlorine in Derived or Secondary Fuels Using High-Temperature (EN)
Technical Data
Min. measurement time | Digestion Mode | Precision | Detector | Sample Supply | Gas supply | Measurement Range | Sample quantity | Limit of Detection | Parameters | Dimension (width x depth x height) | Space requirement (width x depth x height) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
multi EA 4000 C with pyrolysis option | 2 min | High-temperature combustion, catalyst-free (oxygen), Pyrolysis (oxygen/argon) | at 12% C, RSD < 2 % | C: NDIR | horizontal, manual or automated (accessory required) | Oxygen 2.5 Argon | C: 0 - 100 wt-% | up to 3 g | C: 3 ppm | TC, TOC, TIC (accessories required), EC, OC, BOC | 1500 mm x 620 mm x 460 mm | 2000 mm x 700 mm x 550 mm |
multi EA 4000 C | 2 min | High-temperature combustion, catalyst-free | at 12% C, RSD < 2 % | C: NDIR | horizontal, manual or automated (accessory required) | Oxygen 2.5 | C: 0 - 100 wt-% | up to 3 g | C: 3 ppm | TC, TOC, TIC (accessories required) | 1500 mm x 620 mm x 460 mm | 2000 mm x 700 mm x 550 mm |
multi EA 4000 Cl | 3 min | High-temperature combustion, catalyst-free | at 3.5 % Cl, RSD < 2 % | Cl: coulometric titration | horizontal, manual or automated (accessory required) | Oxygen 2.5 Argon | Cl: 0 - 10 wt-% | up to 3 g | Cl: 0.3 ppm | TCl | 1500 mm x 620 mm x 460 mm | 2000 mm x 700 mm x 550 mm |
multi EA 4000 CS | 2 min | High-temperature combustion, catalyst-free | at 12 % C, RSD < 2 %at 2 % S, RSD < 2 % | C: NDIRS: NDIR | horizontal, manual or automated (accessory required) | Oxygen 2.5 | C: 0 - 100 wt-% S: 0 - 20 wt-% | up to 3 g | C: 3 ppm S: 3 ppm | TS , TC, TOC, TIC (accessories required) | 1500 mm x 620 mm x 460 mm | 2000 mm x 700 mm x 550 mm |
multi EA 4000 CS with pyrolysis option | 2 min | High-temperature combustion (oxygen), catalyst-freePyrolysis (oxygen/argon) | at 12 % C, RSD < 2 %at 2 % S, RSD < 2 % | C: NDIRS: NDIR | horizontal, manual or automated (accessory required) | Oxygen 2.5 Argon | C: 0 - 100 wt-% S: 0 - 20 wt-% | up to 3 g | C: 3 ppm S: 3 ppm | TS, TC, TOC, TIC (with accessories), EC, OC, BOC | 1500 mm x 620 mm x 460 mm | 2000 mm x 700 mm x 550 mm |
multi EA 4000 S | 2 min | High-temperature combustion, catalyst-free | at 2 %, RSD < 2 % | S: NDIR | horizontal, manual or automated (accessories required) | Oxygen 2.5 | S: 0 - 20 wt-% | up to 3 g | S: 3 ppm | TS | 1500 mm x 620 mm x 460 mm | 2000 mm x 700 mm x 550 mm |
Order Information
Order number | Description |
---|---|
450-126.568 | multi EA 4000 C with pyrolysis option |
450-126.564 | multi EA 4000 C |
450-126.566 | multi EA 4000 Cl |
450-126.440 | multi EA 4000 CS |
450-126.569 | multi EA 4000 CS with pyrolysis option |
450-126.565 | multi EA 4000 S |
Easy Analysis Even for Complex Matrices
Optimum sample digestion guaranteed
Thanks to high-temperature ceramic (HTC) technology, samples can be fully decomposed up to a temperature of 1,500 °C in a stream of oxygen and without the use of catalysts. For especially complex matrices, the combustion temperature can be temporarily increased up to 1,800 °C by using additives. With these conditions, even thermally stable compounds, such as sulfates and carbides, are fully oxidized. Pyrolysis is an additional function of the multi EA 4000, useful for the analysis of solid waste among others. Pyrolysis enables to distinguish between the environmentally relevant biodegradable organic carbon (BOC) and the residual carbon (RC). Pyrolysis takes place at e.g., 850 °C in an inert gas atmosphere, the BOC is calculated from the difference between TOC and RC content. You can also use the pyrolysis option for the determination of the active carbon content. The flame sensor is an optional accessory for automated chlorine determination. It guarantees complete combustion of the sample. First, the sample is pyrolyzed within inert gas. Then the pyrolysis products are combusted in a pure oxygen stream. The control of the formed flame by the flame sensor is the key to complete combustion and elimination of soot. Automatic TOC and TIC analyses are quicker and easier than ever before! Easily determine the TOC and TIC parameters from one single sample in only one analysis step, fully automatically, quickly and in compliance with standards. Complex manual sample preparations for direct TOC determination are no longer required. Another unique feature is the fully automatic determination of TOC based on the differential method. In combination with the FPG 48 solids sampler, the automatic TIC solids module enables comfortable determination of TOC in samples such as soil, waste and many other materials.
Simultaneous determination of carbon and sulfur
Special wide range NDIR detectors allow for simultaneous determination of carbon and sulfur within a dynamic measuring range from ppm to weight percent while maintaining high linearity. The flexible measuring range allows to determine extremely different contents of sulfur and carbon in one and the same sample. The integrated VITA Flow Management System guarantees reliable NDIR signal evaluation and stable measurement results. The signal is logged regardless of fluctuations in the measuring gas flow so that the evaluation yields reliable results. At the same time, the system registers the flow of the measuring gas and compensates fluctuations by computerized standardization of the NDIR signal to a constant flow rate.
VITA Flow Management System
- Excellent reproducibility of the results
- Clear matrix independence
- High long-term stability of the calibration
- Easier calibration
- Electronic flow control of the system
Accessories
FPG 48 solid autosampler
Solids autosampler for multi EA 4000
Order number: 450-126.574
Cl Upgrade for multi EA 4000
Accessory for the determination of chlorine contents by coulometric titration
Order number: 450-126.567
S-Upgrade for multi EA 4000 C
Accessory for the determination of sulfur contents by NDIR
Order number: 450-126.577
TIC solids module manual
Accessory module for semi-automated, direct determination of total inorganic carbon (TIC) in solid samples by acid decomposition.
Order number: 450-126.575
C Upgrade multi EA 4000 S
Accessory for the determination of carbon contents by NDIR
Order number: 450-126.578
TIC solids module "automatic"
Accessory module for automated, direct determination of total inorganic (TIC) and total organic carbon (TOC) acc. direct and differential method in solid samples
Order number: 450-126.576
Country kit "USA-2" multi EA 4000
Order number: 450-300.002-US
Cl upgrade "sensitive"
Accessory for the determination of high chlorine and AOX contents
Order number: 450-889.501
Country kit "USA-3" multi EA 4000
Order number: 450-300.003-US
C, S-Upgrade for multi EA 4000 Cl
Accessory for the determination of sulfur and carbon by NDIR
Order number: 450-126.581
Country kit "USA-4" multi EA 4000
Order number: 450-300.004-US
S-Upgrade for multi EA 4000 Cl
Accessory for the determination of sulfur by NDIR
Order number: 450-126.580
C-Upgrade for multi EA 4000 Cl
Accessory for the determination of carbon by NDIR
Order number: 450-126.579
Country kit "Australia" multi EA 4000 *
Order number: 450-300.001-AU
Country kit "China" multi EA 4000 *
Order number: 450-300.001-CN
Country kit "EU" multi EA 4000 *
Order number: 450-300.001-EU
Country kit "Swiss" multi EA 4000 *
Order number: 450-300.001-CH
Interface cable for accessories
Order number: 702-889.090
* necessary to operate
Software
multiWin
The self-explanatory multiWin software accompanies the user through all relevant menu points. multiWin is intuitively structured and thus offers the user a comprehensible and simple handling. The Self Check System - an intelligent combination of hardware components and software functions, guarantees uninterrupted and fully automatic operation of the analyzer and its accessories. It monitors and regulates all important system parameters. It immediately points out errors in the configuration of the system and detects unsuitable parameters, thus avoiding low quality results from the very beginning. The software continuously checks the system’s performance and the quality of analysis. multiWin provides free evaluation of sample data even during running measurements, the automatic selection of the optimum calculation function, the fully automatic set up of calibration curves for special applications, the possibility of individual recalculation of results, as well as the clear display of the measurement results. The implemented maintenance counter and intelligent software feature to trigger life time and performance of relevant components make maintenance more predictive, saving time and effort while preventing system failures. Data and parameters can be conveniently managed and stored, and results can be easily forwarded using automatic or manual data import or export functions, including LIMS import and export of data. For elemental analysis with multi EA 5100 and 4000 series the multiWin software includes an extensive library of more than 100 approved, ready to use and stanadard compliant and special application analysis methods. This significantly simplifies analyses according to standard regulations such as ASTM, EPA, DIN, ISO, and UOP. Preconfigured methods eliminate time-consuming method development and allow for fast, correct measurements independant of operators skills.
Feature&Benefits
- Modern and user-friendly Windows™ based control and data evaluation software, available as PC version
- Intuitive user guidance, self-explanatory menu navigation avoids operator mistakes
- Automatic optimization routines, monitoring and control of all relevant system parameters and functions
- Multitasking for free evaluation of sample data even during running measurements
- Special host option allows to control two different systems with the same PC and software
- Different user levels, individual user management
- Easy, quick access menu icons, integrated trainings module, and init-check function enable quick start of operation even for beginners
- Troubleshooting assistant, on-screen help function, implemented service and maintenance modules
- Predictive maintenance – automatic monitoring of maintenance intervals
- Extensive library of ready-made, compliant analysis methods (ASTM, EPA, ISO, etc.) for routine applications and special parameters (e.g. AOX, EC/OC) for multi EA 5100 and 4000 series
- Comprehensive user-oriented functions like multi-point and multi-range calibration, blank correction, recalculation of results, free choice of results dimensions, statistical functions
- Implemented system performance checks – AQA and daily factor functions
- Extensive search, sort and filter functions for methods, calibration and result files
- Versatile export and import functionalities, LIMS, CSV, manual and fully automated etc.
Product | Required | Included |
---|---|---|
multi EA 4000 C with pyrolysis option (450-126.568) | ||
multi EA 4000 C (450-126.564) | ||
multi EA 4000 Cl (450-126.566) | ||
multi EA 4000 CS (450-126.440) | ||
multi EA 4000 CS with pyrolysis option (450-126.569) | ||
multi EA 4000 S (450-126.565) |
Consumables
Order number | Name |
---|---|
402-886.252 | Adapter GL 45 |
402-886.112 | Adapter for drying tube , TIC solid module |
402-886.111 | Adapter for drying tube with angle connector |
402-810.031 | Adsorbent for Cl determination |
402-886.143 | Aluminum part for two-part ceramic hook long, 600 mm |
402-886.142 | Aluminum part for two-part ceramic hook, short, 350 mm |
402-886.131 | Calcium carbonate TC/TIC standard |
402-886.118 | Ceramic boats for HT furnace |
402-891.071 | Ceramic combustion tube multi EA 4000 (HTS 1500) |
402-886.144 | Ceramic hook for FPG 48 in combination with TIC solids module automatic |
402-888.030 | Ceramic hook for manual boat drive |
402-889.721 | Ceramic hook long for FPG 48 |
402-889.705 | Ceramic hook short, 350 mm for autosampler FPG 48 |
402-880.211 | Combination electrode (ceramic) |
402-888.001 | Combustion tube quartz glass multi EA 2000 / 4000 |
402-888.016 | Connection hose for Cl module |
450-889.056 | Consumables set multi EA 4000 CS HTS 1500 |
450-889.057 | Consumables set multi EA 4000 Cl |
402-886.116 | Drying agent for HT furnace |
402-886.129 | Drying tube, GL 45 for HT furnace |
450-888.055 | Extended consumables kit multi EA 4000 HTS 1500 TIC |
402-825.041 | Fork clamp KS 13/2 with locking screw |
402-888.007 | Gasket for lock multi EA |
402-886.010 | Gasket for oxygen lock C/S analysis |
402-881.203 | Glass tube with thread straight, without connectors |
402-825.150 | Halogen absorber , without filling |
402-810.050 | Halogen absorber filling, 11mm 1 refill of the halogen absorber U-tube, I.D. 11 mm |
402-810.083 | Halogen absorber filling, 11mm 5 refills of the halogen absorber U-tube, I.D. 11 mm |
402-886.312 | Halogen absorber filling, 21mm 1 refill of the halogen absorber U-tube, I.D. 21 mm |
402-810.084 | Halogen absorber filling, 21mm 10 refills of the halogen absorber U-tube, I.D. 21 mm |
402-886.005 | Hose for oxygen supply for HT 1300 solids module and multi EA 2000/4000, 4 x 6 mm |
402-815.149 | O-ring for cell lid |
402-886.172 | O-ring 32 x 3 mm |
402-888.031 | Oxygen lance for lock CS , stainless steel |
402-889.714 | Quartz boats multi EA 4000 Cl |
402-888.029 | Quartz glass hook for manual feed |
402-825.044 | Quartz wool |
402-888.018 | Safety vessel Cl determination |
402-815.059 | Screw joint GL 14, lab type |
402-815.136 | Screw joint lab type, GL 18 |
402-881.210 | Set in-line filter M5 |
402-881.213 | Set particle filter (in-line filter) |
450-888.054 | Spare part & consumables, extended set for multi EA 4000 with HTS 1500 |
402-888.020 | Special gasket dust trap |
402-880.213 | Stopper for coulometer cell lid |
402-888.003 | Stopper for sulfuric acid vessel |
402-889.626 | Stopper, small for coulometer cell |
402-888.002 | Sulfuric acid vessel , without split outlet |
402-888.006 | Sulfuric acid vessel with split outlet |
402-886.141 | Two-part ceramic hook long, 600 mm |
402-886.140 | Two-part ceramic hook short, 350 mm |
402-881.013 | U-tube halogen absorber O.D. 21 mm |
402-888.015 | Viton hose for multi EA 2000 / 4000 |
Downloads
Title | Language | Info |
---|---|---|
Brochure multi EA 4000 (EN) | English | PDF, 408 KB |
Broschüre multi EA 4000 (DE) | German | PDF, 407 KB |
Manual multi EA 4000 with HT1500 (DE) | German | PDF, 7 MB |
Manual multi EA 4000 with HT1500 (EN) | English | PDF, 6 MB |
Manual multi EA 4000 with HT1500 (ES) | Spanish | PDF, 7 MB |
Manual multi EA 4000 with HT1500 (FR) | French | PDF, 6 MB |
Operating Manual multi EA 4000 (EN) | English | PDF, 7 MB |
Operating Manual multi EA 4000 (ES) | Spanish | PDF, 7 MB |
Operating Manual multi EA 4000 (FR) | French | PDF, 7 MB |
Product Guide Chemical Analysis (EN) | English | PDF, 886 KB |
Produktkatalog Chemische Analyse (DE) | German | PDF, 909 KB |
The newsletter of Analytik Jena frequently keeps you posted about:
- News
- Trends and developments
- Events