contrAA 800 Series Atomic Absorption. Redefined.
- Fast multi-element analysis
- Accurate results with maximum precision
- Extended measuring range
Multi-element analysis and ease of use at a manageable cost. The contrAA 800 combines the best of standard AAS instruments and ICP-OES spectrometers. Take your demand for precision and performance to the next level and cover the entire range of AAS with a single lamp.
Any Wavelength. Any Element. Any Time.
- Xenon short arc lamp as single light soruce for all applications
- Reduce measurement time by up to 30 % thanks to fast-sequential analysis
- Real simultaneous measurement for selected applications
- Flexible method development with 3D visualization of absorption spectra
- Determination of metals, semi-metals metalloids and even non-metals
Brochures
Title | Language | Info |
---|---|---|
Broschüre contrAA800 (DE) | de | PDF, 472 KB |
Brochure contrAA800 (EN) | en | PDF, 448 KB |
Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
Flyer Calibration Standard Offering (EN) | en | PDF, 265 KB |
High-Resolution Continuum Source (HR-CS) AAS
With the contrAA 800, lamp change in AAS is past. Only one light-intensive lamp, a xenon short arc lamp, covers the entire wavelength range of AAS. A high-resolution spectrometer with CCD detector gives a 3D spectrum and provides a maximum confidence in results and the best detection limits down to the sub ppb range. Fast sequential and multi-element measurements reduce the measurement time and maximize the sample throughput. With the spectral background correction automated by software routines (ABC and CSI-tool) even difficult samples can be analyzed easily. An elaborate design combines this unique optics with all atomization techniques, the flame, graphite furnace and hydride technique in a single platform. A wide range of intelligent accessories maximizes productivity, safety and ease of use for analytical routines. With the fully automated direct solid analysis you can skip the effort of sample digestion.
Products
contrAA 800 D - HR-CS AAS for flame- and graphite furnace techniques
AAS for flame, graphite furnace and hydride techniques combined in one platform
This flexible all-rounder has an automatic atomizer that changes between flame, hydride, and graphite furnace techniques - everything combined in one platform.
Order number: 815-08002-2
contrAA 800 F - HR-CS AAS for flame technique
AAS for flame and hydride techniques
The flame AAS for cost-effective and efficient routine analysis of elements in a wide range of applications.
Order number: 815-08000-2
contrAA 800 G - HR-CS AAS for graphite furnace technique
AAS for graphite furnace and hydride techniques.
Sensitive trace analysis for recurring measurement tasks with higher sample throughput.
Order number: 815-08001-2
Applications
Applications
-
Determination of Element Contents in Wine Using HR-CS Flame AAS (EN)
-
Determination of Metals in Dietary Supplements Using HR-CS Solid AAS (EN)
-
Determination of mineral contents in nonalcoholic (EN)
-
Determination of toxic traces of cadmium, lead, and thallium in food (EN)
-
Bestimmung von Gesamtschwefel in Wein mittels Molekülabsorptionsspektrometrie (MAS) (DE)
-
Determination of total sulfur in wine by molecular absorption spectrometry (MAS) (EN)
Applications
-
Determination of EOF in surface water with molecular absorption spectrometry (EN)
-
Schnell-seuqentielle Analyse giftiger Elemente in Abwasser und Klärschlamm mit der HR-CS AAS (DE)
-
Fast-sequential analysis of toxic elements in wastewater and sewage sludge by HR-CS AAS (EN)
-
A Novel Method for the Fast, Sensitive, and Simple Analysis of Total Fluorine in Wastewater (EN)
Applications
-
Elemental Analysis During the Electroplating Process with contrAA 800 (EN)
Technical Data
Light source | Spectral resolution | Sensitivity | Wavelength range | Optical design | Detector | Background correction | Wavelength precision | Dimension (width x depth x height) | |
---|---|---|---|---|---|---|---|---|---|
contrAA 800 D - HR-CS AAS for flame- and graphite furnace techniques | Xenon short arc lamp | 0.002 nm @ 200 nm | Flame: 0.015 mg/l 1%Abs (Cu 324) Graphite furnace: 0.66 µg/l 1%Abs (Pb 283) | 185-900 nm | High-Resolution Echelle Spectrometer | CCD | Spectral | 0.4 pm | 780 mm x 775 mm x 625 mm |
contrAA 800 F - HR-CS AAS for flame technique | Xenon short arc lamp | 0.002 nm @ 200 nm | Flame: 0.015 mg/l 1%Abs (Cu 324) | 185-900 nm | High-Resolution Echelle Spectrometer | CCD | Spectral | 0.4 pm | 780 mm x 775 mm x 625 mm |
contrAA 800 G - HR-CS AAS for graphite furnace technique | Xenon short arc lamp | 0.002 nm @ 200 nm | Graphite furnace: 0.66 µg/l 1%Abs (Pb 283) | 185-900 nm | High-Resolution Echelle Spectrometer | CCD | Spectral | 0.4 pm | 780 mm x 775 mm x 625 mm |
Order Information
Order number | Description |
---|---|
815-08002-2 | contrAA 800 D HR-CS AAS for flame and graphite furnace techniques |
815-08000-2 | contrAA 800 F HR-CS AAS for flame technique |
815-08001-2 | contrAA 800 G AAS for graphite furnace and technique |
Patented Technology and Ingenious Solutions
Unparalleled flexibility – one lamp, all the elements
A xenon short arc lamp generates a continuous emission spectrum over the entire range of wavelengths of relevance for the AAS. Every element and wavelength can be analyzed at any time as selected in the software. This includes molecular absorption bands that can be used for the analysis of non-metals. Secondary wavelengths with high light intensity are also available, allowing the dynamic range to be extended to higher concentrations. The extraordinary light intensity of the xenon lamp also guarantees an excellent signal-to-noise ratio, thus significantly improving detection limits and precision.
- Multielement analysis across the entire spectrum (185—900 nm)
- Expanded range of application and implementation
- Greater productivity
Unparalleled precision and accuracy – at the highest resolution, with the least interference
The combination of a high-resolution spectrometer and a CCD array detector provides for high-resolution absorption spectra with extremely detailed information. A three-dimensional representation of the spectra provides for the correct evaluation of the absorption lines and their spectral environment. It also provides information on other elements present in the sample that can be measured at the same time as well.
Modern software tools make data evaluation easier. Spectral background and lamp intensity fluctuations are automatically and directly corrected in the spectrum. Interference from other atomic and molecular absorption structures is reduced to a minimum from the outset as a result of the high level of resolution. Complex spectral interferences can be corrected using matrix correction spectra.
- Determination and rapid sequential quantification of all of the elements contained in the sample
- Simple method development
- Reliable results
Accessories
Burner head AC (100 mm) for higher sensitivity in the acetylene/ air flame *
Order number: 810-60056-0
Burner head NO/AC (50 mm) for acetylene/nitrous-oxide or acetylene/air flame *
Order number: 810-60057-0
Sample rack 54 positions for AS-F and AS-FD
Order number: 810-60502-0
Burner fork - for fast replacement of burner heads
Order number: 810-60058-0
Scraper - for automatic burner head cleaning
Order number: 810-60127-0
Segmented Flow Star SFS 6.0 - switching valve
Order number: 810-60129-0
Hg/Hydride System HS 50 - Manual hydride system with flame heated quartz cell atomizer
Cost-effective Hydride system for simple application
Order number: 810-60149-2
SSA 6c Manual solid sampler for contrAA 800
Manual solid sampler for contrAA 800
Order number: 810-60249-2
Air compressor, 50 Hz - to supply AAS with water- and oil- free compressed air *
Order number: 810-60055-0
Air compressor, 60 Hz - to supply AAS with water- and oil- free compressed air *
Order number: 810-60253-0
HydrEA Upgrade Kit for coupling hydride systems HS 55 and HS 60 with graphite furnace AAS
Order number: 810-60509-0
Bench for ICP/AAS for AAS, ICP-OES and ICP-MS instrumentation
Order number: 810-88005-0
Hg cell (tulip) - for improved Hg sensitivity
Order number: 810-60051-0
Hg Plus Upgrade Module for Hg enrichment, extension of Hg/Hydride-Systems HS 55 and HS 60
Order number: 810-60406-0
Hg/Hydride System HS 60 - Flow injection system for Hg and hydride forming elements
Fully automated sample handling for high sample troughput in routine work
Order number: 810-60402-2
Hg/Hydrid-System HS 55 - Batch mode system for Hg and hydride forming elements
Relaible results even for demanding samples
Order number: 810-60404-2
AS-F Autosampler for flame, hydride AAS and CV-AAS/AFS
Standard AAS Autosampler for flame and hydride technology as well as CV-AAS/AFS
Order number: 810-60500-0
AS-FD Autosampler with auto-dilution for flame, hydride AAS and CV-AAS/AFS
Advanced AAS Autosampler with auto-dilution function for flame and hydride technology and CV-AAS/AFS
Order number: 810-60501-0
Sample rack 139 positions for AS-F and AS-FD
Order number: 810-60503-0
SSA 600 automatic solid sampler for contrAA-Series
Automatic solid sampler for contrAA-Series
Order number: 810-60274-0
* necessary to operate
Software
ASpect CS
Optimized for multi-element analysis with HR-CS AAS
ASpect CS is optimized for multi-element analysis with HR-CS AAS and provides straightforward, routine handling of data on a user interface with maximum flexibility even for challenging analyses beyond daily routines. It allows for the simultaneous evaluation of multiple element lines in one spectrum and free definition of the integration ranges of individual lines. Advanced correction algorithms automate the process of correcting both complex structured backgrounds and spectral interferences (CSI tool), providing more reliable figures than ever before. You can visualize your measurements and optimize your methods thanks to the three-dimensional, high-definition display of the spectra (HD Spectrum).
- SOPs for easy method development
- A large range of innovative evaluation methods such as the CSI tool
- High safety measures and Good Laboratory Practice (GLP)
- FDA 21 CFR Part 11 compliance (optional)
Product | Required | Included |
---|---|---|
contrAA 800 D - HR-CS AAS for flame- and graphite furnace techniques (815-08002-2) | ||
contrAA 800 F - HR-CS AAS for flame technique (815-08000-2) | ||
contrAA 800 G - HR-CS AAS for graphite furnace technique (815-08001-2) |
FDA 21 CFR Part 11 Compliance for ASpect CS
Order number: 815-01003-2
The ASpect CS software with the FDA 21 CFR Part 11 module fully complies with FDA requirements. User rights management and individual passwords ensure that the system can only be accessed by authorized persons. All important events, such as logon/logoff, measurements, calibrations, and messages generated by the Self Check System, are recorded in the Audit Trail. Measured data can undergo routine review and approval using electronic signatures.
Product | Required | Included |
---|---|---|
contrAA 800 D - HR-CS AAS for flame- and graphite furnace techniques (815-08002-2) | ||
contrAA 800 F - HR-CS AAS for flame technique (815-08000-2) | ||
contrAA 800 G - HR-CS AAS for graphite furnace technique (815-08001-2) |
Consumables
Order number | Name |
---|---|
810-60258-0 | Consumable set F for Flame technique novAA/contrAA/ZEEnit series |
810-60066-0 | Consumable set G for graphite technique novAA/contrAA |
810-60508-0 | Consumables Set H for Hydride Systems |
407-A81.020 | Graphite pipetting insert for novAA / contrAA series |
407-A81.011 | Graphite tubes - pyrolytically coated |
407-A81.025 | Graphitetube with PIN-platform pyrolytically coated |
407-A81.021 | Ceramic O-rings for furnace |
702-A63.624 | Cleaning strips for flame AAS |
702-A63.625 | Cleaning wires for flame AAS |
407-111.860 | Impact bead (standard, short) for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III) |
407-111.006 | Inlet tube (PTFE), manual work for mixing chamber (black, Ryton)-nebulizer (graphite )-system (III) |
407-111.501 | Nebulizer (graphite) for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III) |
407-111.402 | Set o-rings organic samples for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III) |
407-143.021 | Set sealing rings for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III) |
407-111.837 | Waste tube siphon for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III) |
407-1508.108 | Level sensor, organic samples for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III) |
407-10-1610-105-25 | XBO-exchange unit for contrAA 800 series |
Downloads
Title | Language | Info |
---|---|---|
12515110_CE_Declaration_of_Conformity_2017_contrAA800.pdf | English | PDF, 707 KB |
Brochure contrAA800 (EN) | English | PDF, 448 KB |
Broschüre contrAA800 (DE) | German | PDF, 472 KB |
Flyer Calibration Standard Offering (EN) | English | PDF, 265 KB |
Operating Manual contrAA 800 (DE) | German | PDF, 16 MB |
Operating Manual contrAA 800 (IT) | Italian | PDF, 16 MB |
Product Guide Chemical Analysis (EN) | English | PDF, 886 KB |
Produktkatalog Chemische Analyse (DE) | German | PDF, 909 KB |
Technical Data contrAA 800 (EN) | English | PDF, 217 KB |
Technical Data contrAA 800 (EN) | English | PDF, 217 KB |
The newsletter of Analytik Jena frequently keeps you posted about:
- News
- Trends and developments
- Events