CyBio SELMA

plus d'images

Overview

CyBio® SELMA — Semi-automatic 96- or 384-fold pipettor with minimal required space

Precise and semi-automatic pipettor with 96 or 384 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.

  • Fast and precise processing of 96- and 384-well microplates without computer
  • Simple and intuitive handling with touch screen
  • Easy and fast tip changing with ready to use CyBio® TipTrays
  • Error-free and reproducible results due to 96 or 384 parallel pistons and proven tip sealing principle
  • Reminder function and automatic use of pipetting heights and parameters for the processing of several microplates
  • An open design allows the use of external devices like shaker, vacuum chamber, heating adapters, etc.
  • Applications such as replication and reformatting of microplates as well as serial dilutions can be execute in seconds

Brochure

Variants

CyBio® SELMA 96/25 µl
Semi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 0.5 till 25 µl and 2 working positions for 96 well plates

CyBio® SELMA 96/60 µl
Semi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 1 till 60 µl and 2 working positions for 96 well plates

CyBio® SELMA 96/250 µl
emi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 5 till 250 µl and 2 working positions for 96 well plates

CyBio® SELMA 96/1000 µl
Semi-automated pipetting station, instrument system stand alone, including a 96 channel pipetting head from 10 till 1000 µl and 2 working positions for 96 well plates

CyBio® SELMA 384/25 µl
Semi-automated pipetting station, instrument system stand alone, including a 384 channel pipetting head from 0.5 till 25 µl and 2 working positions for 384 well plates

CyBio® SELMA 384/60 µl
Semi-automated pipetting station, instrument system stand alone, including a 384 channel pipetting head from 1 till 60 µl and 2 working positions for 384 well plates

Specifications

Pipetting heads   

Precision* (cv in %)

96/1000 µl pipetting head:

25-100 µl ≤ 2%

100-1000 µl ≤ 1%

96/250 µl pipetting head:

10-25 µl ≤ 2%

25-250 µl ≤ 1%

96- or 384/60 µl pipetting heads:

3-5 µl ≤ 2%

5-60 µl ≤ 1%

96- or 384/25 µl pipetting heads:

2-5 µl ≤ 2%

5-25 µl ≤ 1%

*The specification of precision and trueness is based on the Analytik Jena internal gravimetric and photometric standard measurement procedure, which is published as Annex B7 in the ISO IWA 15 document ” Specification and method for the determination of volumetric performance of automated liquid handling systems“ (www.IWA15.org). The Application Note „Photometric and Gravimetric Liquid Handling Check Procedure to determine the Random Error (Precision) and the Systematic Error (Accuracy) of Automated Liquid Handling Systems (ALHS)“ describes this measuremet procedure in detail.
Every modification of this method may influence the results.

Technical Data

CyBio® SELMA 96CyBio® SELMA 384
Weightapprox 15 kg
CyBio® SELMA 96/1000 µl: ca. 20 kg
Positions22
Pipetting Channels96 channels in parallel384 channels in parallel
Pipetting Tips Disposable tipsDisposable tips
Plate Formats96 / 384 (optional accessories are available)384
Footprint (W x D in mm)307 x 325307 x 325
Height (mm)CyBio® SELMA 96: 480
CyBio® SELMA 96/1000 µl: 520
480
Column wise pipettingyes (optional accessory)Yes (optional accessory)
Volume Range0.5-1000 µl0.5 - 60 µl

Accessories

8-channel magazine

The 8-channel tip magazine enables the realization of serial dilutions and the work in columns at CyBio® SELMA.

384-well plate adapter

This microplate adapter features a slide function to process 384-well plates on both positions of the CyBio® SELMA 96-channel versions. The adapter is further supporting the work with 384-well plates by showing the currently processed index.

Side Touch Adapter

The Side-Touch adapter allows a manual spring loaded movement of the microplate in X- and Y- direction to perform a side-touch of the pipetting tips. After releasing the adapter, it will move back to a centered position for a normal workstation.

Microplate adapters for REMP plates or Protein Applications

With these microplate adapters, it is possible to process REMP plates or to prefill GREINER CrystalQuick® plates and Hampton Research MRC 2 Well plates for Protein Crystallization on the CyBio® SELMA. The specific adapters are positioning the microplates correctly under the tips and can be used on both CyBio® SELMA positions.

Special CyBio® SELMA Worktable

This special 2-splitted table will change working position 1 of the CyBio® SELMA in order to work with high reservoirs and other accessories, like vacuum chambers.

Videos

CyBio® SELMA | Manual Pipetting

Precise and semi-automatic pipettor with 96 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.

CyBio® SELMA | Automation Pipetting

Precise and semi-automatic pipettor with 96 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.

CyBio® SELMA | Dispensing

Precise and semi-automatic pipettor with 96 pipetting channels for easy and fast filling of 96- and 384-well microplates without the use of a computer. Applications like replication and reformatting, medium exchange as well as serial dilution can be executed reproducible and convenient.

Product Inquiry

Are you interested in receiving more information about this product?

Product inquiry

Der Analytik Jena-Newsletter informiert Sie regelmäßig über:

Nichts mehr verpassen