multi EA 5100 for micro-elemental analysis Your Entire C/N/S/X Lab in One Device
- Unparalleled application variety without the need for time-consuming device modification
- Unattended operation and reliable results with the Self Check System
- Smart safety features and pre-configured methods simplify your analysis
- One analyzer for all applications, no matter if the sample is solid, liquid or gaseous.
- Vertical and horizontal combustion combined in one system
The multi EA 5100 is your flexible all-rounder for sulfur, nitrogen, chlorine, and carbon analysis in solids, liquids, and gases. Benefit from the combination of outstanding robustness and sensitivity, best service, and cost-effective high-throughput analysis in every matrix – in QC laboratories, in research, or in contract analysis.
Versatile, Fast, and Sensitive – Elevate Your Measurement Performance
The modular design allows the system to be adapted to individual requirements. The basic unit can be extended at any time. Mix and match the multi EA 5100 accessory modules to suit your needs. The double furnace technology lets you achieve the best results for every sample matrix. Thanks to the easy-to-use tilting mechanism the analyzer can switch from vertical to horizontal combustion in few minutes. The multi EA 5100 is equipped with a safety system that guarantees maximum operational safety and economic life of crucial system components. Relevant system parameters are automatically monitored and optimized, guaranteeing a trouble-free and safe operation. The auto-protection system protects the analyzer from damage caused by particles, aerosols, and liquids. Optimal combustion for accurate measurements, the flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation. Samples can be analyzed quickly and reliably.
- Double furnace – vertical and horizontal combustion combined in one system
- Intuitive user guidance, self-explanatory menu navigation
- Self Check System – automatic monitoring, adaptation and regulation of important system parameters
- Flow management system with High performance gasbox – stable gas flows, optimal digestion, prevention of soot formation by automatic leak check
- Auto Protection system – save operation, extension of components life
- Plug-and-Start technology – automatic recognition of active system configuration
- Flame sensor technology – ensuring fastest soot-free boat combustion independant of sample quantity and sample matrix
Brochures
Title | Language | Info |
---|---|---|
Brochure multi EA 5100 Elemental Analysis (EN) | en | PDF, 406 KB |
Produktkatalog Chemische Analyse (DE) | de | PDF, 909 KB |
Product Guide Chemical Analysis (EN) | en | PDF, 886 KB |
Flyer Accessories for multi EA 5100 (EN) | en | PDF, 304 KB |
Flyer Zubehöre multi EA 5100 (DE) | de | PDF, 323 KB |
Broschüre multi EA 5100 Elementanalytik (DE) | de | PDF, 401 KB |
Fast, Versatile, Sensitive
The multi EA 5100 guarantees competitive advantage of your lab in terms of cost-effectiveness and analysis quality. Fast analysis is possible in three minutes for liquids and six minutes for solids. With a high sample throughput up to 160 liquid samples and up to 90 solid samples per day, costs are kept very low. Reduced consumption of consumables and less time spent on maintenance, minimize costs even further. C/N/S/X testing is carried out in one analysis cycle, the change between C/N/S and X determination is fully automatic, with no conversion of the instrument required. The unmatched detector diversity of sulfur, nitrogen, carbon, and chlorine opens up a wide range of applications and offers the perfect solution for every elemental analysis task. The modular principle allows for the system to be designed individually – an extension is possible at any time should your requirements change. The HiPerSens detection provides for a broad linear measuring range and lowest limits of detection.
Flexible automation possibilities for a high sample throughput reduce the costs per analysis considerably. A wide range of accessories is offered to boost analysis throughput. Available accessories include an automatic boat drive (ABD) with cooled sample port for the automatic introduction of liquid and solid samples. It´s integrated flame sensor guarantees matrix-optimized, quantitative combustion and prevents soot formation, thereby solving a problem common to other conventional instruments. With this technology, samples can be analyzed quickly and reliably, even if their characteristics are unknown. A multi matrix sampler (MMS) is available for automatic introduction of up to 112 liquids or 35 solids, an autoinjector for safe semi-automated injection of liquids up to 100 μl, ideal for small sample series. For LPG and gas analysis, three different matrix-optimized modules are available. You can choose between the GSS module, a gas sampling system for introduction of unpressurized or pressurized gas samples, the LPG 2.0 module for direct dosing of pressurized liquefied gases, and the GSS/LPG combi module for dosing of liquefied and pressurized gases with separate sample branches to prevent cross-contamination. With its broad application spectrum and smart features, the multi EA 5100 is ideal for industrial control labs, contract labs and state authorities in the oil and gas, petrochemical and chemical industries. Applications include process control, material testing, and waste management. Features such as flame sensor technology for matrix-optimized sample digestion – including most difficult matrices such as oils, VGO, polymers and liquefied gases – and the integrated method library are indispensable for easy routine analysis.
Applications
Applications
-
Diesel Fuels and Fuel Additives – Interference-Free Determination of Sulfur Traces According to ASTM D5453 (EN)
-
Heavy Fuel Oil, Feed Materials and Residues – Trustable Determination of High Nitrogen Contents in Viscous, Complex Matrices (EN)
-
Elemental analysis for N/S/Cl determination in biofuels (EN)
-
Determination of Total Volatile Sulfur in Gaseous Hydrocarbons and Liquefied Petroleum Gases According to ASTM D6667 resp. ASTM D7551 (EN)
-
Determination of Ultra Low Nitrogen in Aromatic Hydrocarbons (EN)
-
Determination of Nitrogen Contents in Petroleum Products (EN)
-
Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons DIN51444 (EN)
-
Determination of Total Sulfur in Aromatic Hydrocarbons and Related Chemicals (EN)
-
Standard Test Method for Determining Organic Chloride STM D5808 (EN)
-
Ultra-sensitive High-throughput TS Analysis in Light Hydrocarbons ASTM D5453 (EN)
-
Determination in Light Hydrocarbons and Engine Fuel ASTM D5453 (EN)
-
Bestimmung des Gesamtschwefels mittels UV-Fluoreszenz nach ASTM D7183 (DE)
-
Standard-Testmethode zur Bestimmung von organisch-gebundenem Chlor ASTM D5808 (DE)
-
Elementaranalyse zur N/S/Cl-Bestimmung in Biokraftstoffen und ihren Ausgangsstoffen (DE)
Applications
-
Determination of Different Chlorine Parameters in Palm Oil (EN)
-
Elemental analysis for N/S/Cl determination in biofuels (EN)
-
Determination of N/S/Cl Contents in Lactic Acid (EN)
-
Total Nitrogen Determination in Sugar and Starch by Catalyst-Free High-Temperature Combustion (EN)
-
Elementaranalyse zur N/S/Cl-Bestimmung in Biokraftstoffen und ihren Ausgangsstoffen (DE)
-
Détermination de différents paramètres de chlore dans l‘huile de palme avec l‘analyseur élémentaire multi EA 5100 (FR)
Applications
-
Determination of N/S/Cl Contents in Lactic Acid (EN)
-
Measurement of Soot in Ambient Air Based on VDI 2465-2 (EN)
Applications
-
Determination of N/S/Cl Contents in Lactic Acid (EN)
-
Determination of Total Sulfur and Total Nitrogen in Synthetic Caoutchouc (EN)
-
Determination of Total Chlorine in Different Types of Hydraulic Fluids (EN)
-
Ultra-sensitive High-throughput TS Analysis in Light Hydrocarbons ASTM D5453 (EN)
-
Determination in Light Hydrocarbons and Engine Fuel ASTM D5453 (EN)
-
Trace Nitrogen Determination in Adipic Acid (EN)
Applications
-
Test Method for Total Chlorine in New and Used Petroleum Products (EN)
Technical Data
Min. measurement time | Digestion Mode | Sample Pressure | Injection Volume | Detector | Sample Supply | Gas supply | Measurement Range | Sample quantity | Limit of Detection | Parameters | Dimension (width x depth x height) | Space requirement (width x depth x height) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
multi EA 5100 for micro-elemental analysis | 3 min | High-temperature combustion, catalyst-free | gas: up to 200 bar LPG: up to 35 bar | liquids: 0 - 500 µL gases: 0 - 100 mL LPG: 0 - 50 µL | S: UVFDS: coulometric titrationN: CLDCl: coulometric titrationC: NDIR | horizontal and vertical | Oxygen 4.5 and Argon 4.6 | S (UVFD): 0 - 1 wt-% S (coulometry): 0 - 4 wt-% N: 0 - 1 wt-% Cl: 0 - 10 wt-% C: 0 - 100 wt-% | solids: 0 - 110 mg | S (UVFD): 5 ppb S (coulometry): 600 ppb N: 10 ppb Cl: 50 ppb C: 100 ppb | TS, TN, TC, TOC, TIC, EC/OC, TCl, TICl, TOCl, AOX, EOX (depending on accessories) | 510 mm x 550 mm x 470 mm | 600 mm x 600 mm x 600 mm |
Order Information
Order number | Description |
---|---|
450-300.011 | multi EA 5100 for micro-elemental analysis C/N/S/X determination in one device |
"Each sample is fully combusted and residue-free. That is the best foundation for reliable measurement results. We also save a lot of time in method development since, thanks to the flame sensor, each sample can be oxidized quickly and easily in a variety of quantities without precise knowledge of its combustion characteristics. We are also well prepared for the future when it comes to meeting even higher quality requirements for our products."
Peter Frenzel, Head of Analytics and Quality Manager at The Dow Chemical Company
Technologies Making Lab Life Easier
Double Furnace Technology
The double furnace technology allows to benefit from the advantages of the vertical and horizontal digestion in one system. The easy-to-use tilting mechanism enables the system to be optimally adapted to your sample. For rapid and precise determination of liquids and gases, particularly in the trace range, the use of vertical systems has become standard. With the increase in complexity, volatility and viscosity of the samples, however, it is necessary to use the horizontal mode. The multi EA 5100 gives you unlimited application versatility, matrix optimized combustion, minimal maintenance effort, and best results for all sample types.
HiPerSens Detection
With one wide adjustment-free operation range the detectors are suitable for all concentrations. The HiPerSens detection combines highest sensitivity in ultra-trace analysis with a wide linearity up to the upper end of operation range. Thus high and low element contents can be processed together in the same sequence, only one method is required. Samples with high concentrations can be analyzed directly without dilution.
Flame Sensor
Flame Sensor technology for automatic process optimization provides the fastest possible analysis for all samples in horizontal mode. Only one method is required for all matrices of the same state of aggregation! It ensures maximum operational safety and soot-free combustion for even high sample quantities. This generates reliable measurement results with less replicates.
Auto-Protection
The Auto-Protection effectively prevents the system against damages caused by particles, aerosols and liquids. It features effective cleaning and drying of the reaction gases and monitoring and protection functions for highest analysis safety and minimum maintenance effort.
Accessories
Country kit Australia *
Order number: 450-300.011-AU
Country kit China *
Order number: 450-300.011-CN
Country kit EU basic unit *
Order number: 450-300.011-EU
Country kit Japan basic unit *
Order number: 450-300.011-JP
Country kit Swiss basic unit *
Order number: 450-300.011-CH
Country kit UK basic units and accessories *
Order number: 450-300.011-GB
Country kit USA basic unit *
Order number: 450-300.011-US
C/N/S High Performance drier kit multi EA 5100 *
Maintenance-free dryer for sulfur, nitrogen and carbon determination
Order number: 450-300.012
C module 5100
Accessory for the determination of carbon contents by NDIR
Order number: 450-300.028
Cl module 5100
Accessory for the determination of chlorine contents by coulometric titration
Order number: 450-300.023
Extension kit Cl "sensitive"
For the determination of high chlorine contents and AOX
Order number: 450-300.025
Extension kit Cl "high concentration"
For the determination of very high chlorine contents
Order number: 450-300.026
Extension kit Cl "high sensitive"
For the determination of very low chlorine contents
Order number: 450-300.024
N module 5100
Order number: 450-300.022
S module basic
Accessory for the determination of sulfur contents by UV fluorescence
Order number: 450-300.021
S module coulometric
Accessory for the determination of sulfur contents by coulometric titration
Order number: 450-300.027
S module MPO
Accessory for the determination of sulfur in fuels and refinery samples by UV fluorescence
Order number: 450-300.020
TOC module 5100
Accessory for the determination of TC, TOC and TIC in wastewater analysis
Order number: 450-300.029
Automatic Boat Drive - ABD without flame sensor technology
Multi-Matrix sample supply system for the horizontal operation mode for multi EA 5100 and multi X 2500
Order number: 450-126.416
Boat sensor for MMS and autoX 112 sampler
Accessory for MMS and autoX - ensures trouble-free routine operation in AOX and solids analysis
Order number: 450-889.204
Cover for multi matrix sampler
Accessory for Multi Matrix Sampler - prevention of sample loss and contamination effects in solids/AOX analysis
Order number: 450-900.408
Liquids kit "TMP" for MMS 5100
Accessory for MMS 5100 - with cooling option for safe and quantitative dosing of very light volatile liquids and heating option for comfortable and troublefree dosing of viscous liquids
Order number: 450-300.031
Liquids kit for MMS 5100
Accessory for MMS 5100 - for dosing of liquid samples
Order number: 450-300.033
MMS-T temperature-controlled autosampler
Temperature-controllable liquids autosampler for multi EA 5100
Order number: 450-900.453
Multi Matrix Sampler - MMS
Versatile multi-matrix autosampler for liquids, solids, TOC, AOX and EOX samples for multi EA 5100
Order number: 450-300.030
Solids kit for MMS
Accessory for MMS and autoX 112 - for automated dosing of solids, highly viscous liquids and AOX samples
Order number: 450-300.034
Solids kit T for MMS T
Accessory for MMS-T - for dosing of solids, highly viscose liquids, and AOX samples
Order number: 450-900.454
TOC kit for MMS
Accessory for MMS - enables automatic determination of TC and NPOC contents in wastewater analysis
Order number: 450-300.035
Autoinjector - type AI-EA
Basic, robust semi-automated sample supply for liquids for multi EA 5100
Order number: 450-900.461
Autoinjector - without syringe
Innovative, advanced semi-automated sample supply for liquids for multi EA 5100
Order number: 450-900.403
Automatic Boat Drive - ABD with flame sensor technology
Multi-Matrix sample supply system for the horizontal operation mode with flame sensor for multi EA 5100
Order number: 450-300.013
Gas sampling system - GSS for multi EA 5000 / 5100
The impressing allrounder in gas analysis for multi EA 5100
Order number: 450-126.420
GSS/LPG combi module for multi EA 5000 / 5100
2-in-1 combination of LPG and pressurized gas sampling system for multi EA 5100
Order number: 450-126.418
Adapterbox for GSS module
Accessory for GSS module enabling analysis of pressurized gases
Order number: 450-007.531
Extension "sample in" (female)
Order number: 450-520.283
Extension "sample in" (male)
Order number: 450-520.267
Gas leak detector "sniffer"
Order number: 450-890.032
LPG module 2.0 multi EA 5000 / 5100
The safe solution for demanding high-pressure LPG applications for multi EA 5100
Order number: 450-900.465
EC/OC set
For separate determination of elemental and organically-bound carbon
Order number: 450-900.402
Flow test kit
For checking gas flows and gas leaks
Order number: 402-889.652
* necessary to operate
Software
multiWin Software
Order number: 450-011.803
The self-explanatory multiWin software accompanies the user through all relevant menu points. multiWin is intuitively structured and thus offers the user a comprehensible and simple handling. The Self Check System - an intelligent combination of hardware components and software functions, guarantees uninterrupted and fully automatic operation of the analyzer and its accessories. It monitors and regulates all important system parameters. It immediately points out errors in the configuration of the system and detects unsuitable parameters, thus avoiding low quality results from the very beginning. The software continuously checks the system’s performance and the quality of analysis. multiWin provides free evaluation of sample data even during running measurements, the automatic selection of the optimum calculation function, the fully automatic set up of calibration curves for special applications, the possibility of individual recalculation of results, as well as the clear display of the measurement results. The implemented maintenance counter and intelligent software feature to trigger life time and performance of relevant components make maintenance more predictive, saving time and effort while preventing system failures. Data and parameters can be conveniently managed and stored, and results can be easily forwarded using automatic or manual data import or export functions, including LIMS import and export of data. For elemental analysis with multi EA 5100 and 4000 series the multiWin software includes an extensive library of more than 100 approved, ready to use and stanadard compliant and special application analysis methods. This significantly simplifies analyses according to standard regulations such as ASTM, EPA, DIN, ISO, and UOP. Preconfigured methods eliminate time-consuming method development and allow for fast, correct measurements independant of operators skills.
Features & Benefits
- Modern and user-friendly Windows™ based control and data evaluation software,
- Available as PC version
- Intuitive user guidance with self-explanatory menu navigation avoids operator mistakes
- Automatic optimization routines, monitoring and control of all relevant system parameters and functions
- Multitasking for free evaluation of sample data, even during running measurements
- Special host option allows to control two different systems with the same PC and software
- Different user levels, individual user management
- Easy, quick access menu icons, integrated trainings module, and init-check function enable quick start of operation even for beginners
- Troubleshooting assistant, on-screen help function, implemented service and maintenance modules
- Predictive maintenance – automatic monitoring of maintenance intervals
- Extensive library of ready-made, compliant analysis methods (ASTM, EPA, ISO, etc.) for routine applications and special parameters (e.g. AOX, EC/OC) for multi EA 5100 and 4000 series
- Comprehensive user-oriented functions like multi-point and multi-range calibration, blank correction, recalculation of results, free choice of results dimensions, statistical functions
- Implemented system performance checks – AQA and daily factor functions
- Extensive search, sort and filter functions for methods, calibration and result files
- Versatile export and import functionalities, LIMS, CSV, manual and fully automated etc.
Product | Required | Included |
---|---|---|
multi EA 5100 for micro-elemental analysis (450-300.011) |
Consumables
Order number | Name |
---|---|
450-889.324 | Consumables & spare parts (extended) kit N module multi EA 5100 |
402-889.591 | 40 µL syringe for Autoinjector |
402-889.589 | 10 µL syringe for autoinjector |
402-889.592 | 100 µL syringe for Autoinjector |
402-889.590 | 20 µL syringe for autoinjector |
402-300.100 | 100 µL special syringe for autoinjector AI-EA |
402-300.103 | 50 µL special syringe for autoinjector AI-EA |
402-820.044 | Air filter for membrane dryer pump |
402-889.527 | Auto-Protection valve assembly with bypass, complete |
450-889.323 | Consumables & spare parts kit autoinjector type AI |
450-889.321 | Consumables & spare parts kit Cl "sensitive" and " high concentration" |
450-889.320 | Consumables & spare parts kit Cl module 5100 - "high sensitive-4 electrode" |
450-889.304 | Consumables & spare parts kit for GSS/LPG combi module |
450-889.316 | Consumables & spare parts kit for horizontal operation (ABD) |
450-889.306 | Consumables & spare parts kit for liquids autosampler MMS |
450-889.313 | Consumables & spare parts kit for multi EA 5100 |
450-889.317 | Consumables & spare parts kit for N module |
450-889.319 | Consumables & spare parts kit for S module 5100 coulometric |
450-889.325 | Consumables & spare parts kit for S module UVFD |
450-889.318 | Consumables & spare parts kit for S module, UVFD with MPO |
450-889.315 | Consumables & spare parts kit for vertical operation |
450-889.305 | Consumables & spare parts kit GSS multi EA 5000 / 5100 |
450-889.303 | Consumables & spareparts kit for LPG type 2.0 |
402-007.513 | FAST connector , angled |
402-820.110 | FEP tubing |
402-881.028 | Finger-Tight -Set |
402-801.317 | Fuses - T 10 A |
402-822.118 | Heat protection gloves |
402-889.510 | Multi purpose combustion tube |
402-820.129 | Oxygen, Argon gas supply resp. water tubing |
402-889.674 | Quartz sample boats 40 x 9 mm |
402-889.673 | Quartz sample boats with downholder 40 x 9 mm |
402-825.044 | Quartz wool |
402-300.012 | Replacement C/N/S drier multi EA 5100 * |
402-889.092 | Sample vials 2 mL |
402-889.306 | Screw cap with hole GL 18 |
402-889.050 | Septa, O.D. 12.5 mm |
402-889.558 | Set auto protection filter |
402-889.557 | Set sealing disks , 17 mm |
402-889.091 | Set snap caps for 2 mL sample vials |
402-889.583 | Special sealing auto-protection system |
402-950.028 | Tubing kit multi EA 5000 / 5100 |
402-825.045 | Tweezers , straight, truncated |
* necessary to operate
Downloads
Title | Language | Info |
---|---|---|
12557341_CE-Declaration_of_Conformity_2020_multi_EA5100.pdf | English | PDF, 202 KB |
Brochure multi EA 5100 Elemental Analysis (EN) | English | PDF, 406 KB |
Broschüre multi EA 5100 Elementanalytik (DE) | German | PDF, 401 KB |
Flyer Accessories for multi EA 5100 (EN) | English | PDF, 304 KB |
Flyer Zubehöre multi EA 5100 (DE) | German | PDF, 323 KB |
Operating Manual Cl Module (DE) | German | PDF, 5 MB |
Operating Manual Cl Module (EN) | English | PDF, 5 MB |
Operating Manual CLD 5000 (DE) | German | PDF, 2 MB |
Operating Manual multi EA 5100 (DE) | German | PDF, 18 MB |
Operating Manual multi EA 5100 (EN) | English | PDF, 18 MB |
Operating Manual multi EA 5100 (ES) | Spanish | PDF, 18 MB |
Operating Manual multi EA 5100 (FR) | French | PDF, 18 MB |
Operating Manual multi EA 5100 (RU) | Russian | PDF, 19 MB |
Product Guide Chemical Analysis (EN) | English | PDF, 886 KB |
Produktkatalog Chemische Analyse (DE) | German | PDF, 909 KB |
Technical Data multi EA5100 (EN) | English | PDF, 194 KB |
TechNote Multi EA 5100 Flame Sensor (EN) | English | PDF, 223 KB |
The newsletter of Analytik Jena frequently keeps you posted about:
- News
- Trends and developments
- Events